Parsonics Corp. ULTRASONIC AIR TRANSDUCERS SPECIFICATIONS

Parsonics Corp. Air Transducers cover the frequency range of 20 to 500kHz for use in Liquid Level Monitoring, Proximity, Machine Control, Vehicle Guidance, Counting, Gauging and a host of other applications encounteredin the Process Control Industries. The transducers are completely sealed, watertight and designed for years of trouble-free operation. Most of thetransducers are narrow beam angle without side lobes for good target acquisition in the cluttered environment.

Thermal Sensors can be installed in the transducers to provide temperature measurements. Instruments can use this feature to provide accurate distance measurements when the sound velocity changes with temperature. Matching driver transformers can be supplied for the transducers to make instrument design easier. ANSI flange mounts and 3-A Sanitary Transducers are available for certain models.


Ultrasonic Transducer Models
2308

2308A
2308F
4026
4075
7516
20006
20006 ABS
2007T
42005
1418
2010


 Model Number 2308
Frequency kHz 23
Capacitance pf6000
Insertion Loss db at range listed-76 6'
Maximum Drive Volts p-p 450
Rise Time Microseconds 2000
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 8
Bandwidth -6 db in kHz 1.5
 Power Input at rated Voltage Watts RMS 13
Typical Range* 5 - 100'
Housing Material PVC
Transmission Window Buna-N or PVC

Back to top


 Model Number 2308A
Frequency kHz 25
Capacitance pf 6000
Insertion Loss db at range listed -58 5'
Maximum Drive Volts p-p 450
Rise Time Microseconds 1500
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 8
Bandwidth -6 db in kHz 2.0
 Power Input at rated Voltage Watts RMS 16
Typical Range* 2 - 115'
Housing Material PVC
Transmission Window PVC

Back to top


 Model Number 2308F
Frequency kHz 25
Capacitance pf 6000
Insertion Loss db at range listed -50 5'
Maximum Drive Volts p-p 450
Rise Time Microseconds 1500
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 8
Bandwidth -6 db in kHz 2.4
 Power Input at rated Voltage Watts RMS 16
Typical Range* 2 - 130'
Housing Material PVC
Transmission Window Polyfoam

(note 2)

Back to top


 Model Number 4026
Frequency kHz 38
Capacitance pf 1500
Insertion Loss db at range listed -87 15"

-76 15" w/horn

Maximum Drive Volts p-p 450
Rise Time Microseconds 500
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 26

16 w/horn

Bandwidth -6 db in kHz 3.5
 Power Input at rated Voltage Watts RMS 12
Typical Range* 1 - 15'

1 - 28' w/horn

Housing Material PVC
Transmission Window PVC

Back to top


 

 Model Number 4075
Frequency kHz 40
Capacitance pf 320
Insertion Loss db at range listed N/A

(note 1)

Maximum Drive Volts p-p 50
Rise Time Microseconds N/A
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 75

transmit only

Bandwidth -6 db in kHz 0.9
 Power Input at rated Voltage Watts RMS 0.1
Typical Range* 15 '
Housing Material Aluminum
Transmission Window Aluminum

Back to top


 Model Number 7516
Frequency kHz 75
Capacitance pf 3000
Insertion Loss db at range listed -78 15"

-64 15" w/horn

Maximum Drive Volts p-p 350
Rise Time Microseconds 400
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 12

5 w/horn

Bandwidth -6 db in kHz 5
 Power Input at rated Voltage Watts RMS 15
Typical Range* 1 - 15'
Housing Material PVC or Teflon
Transmission Window PVC or Teflon

Back to top


 Model Number 20006
Frequency kHz 180
Capacitance pf 300
Insertion Loss db at range listed -78 15"
Maximum Drive Volts p-p 250
Rise Time Microseconds 100
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 7
Bandwidth -6 db in kHz 30
 Power Input at rated Voltage Watts RMS 2.5
Typical Range* 4" - 4'
Housing Material PVC or Teflon
Transmission Window Neoprene or Teflon

Back to top


 Model Number 20006 ABS
Frequency kHz 180
Capacitance pf 300
Insertion Loss db at range listed -78 15"
Maximum Drive Volts p-p 250
Rise Time Microseconds 300
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 7
Bandwidth -6 db in kHz 12
 Power Input at rated Voltage Watts RMS 2
Typical Range* 6" - 5'
Housing Material ABS
Transmission Window ABS

Back to top


 Model Number 2007T
Frequency kHz 180
Capacitance pf 300
Insertion Loss db at range listed -78 15"
Maximum Drive Volts p-p 250
Rise Time Microseconds 100
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 7
Bandwidth -6 db in kHz 18
 Power Input at rated Voltage Watts RMS 2
Typical Range* 4" - 4'
Housing Material Teflon
Transmission Window Teflon

Back to top


 Model Number 42005
Frequency kHz 420
Capacitance pf 650
Insertion Loss db at range listed -80 8"
Maximum Drive Volts p-p 150
Rise Time Microseconds 100
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 6
Bandwidth -6 db in kHz 20
 Power Input at rated Voltage Watts RMS 4
Typical Range* 3" - 18"
Housing Material ABS
Transmission Window ABS

Back to top


 Model Number 1418
Frequency kHz 14.6
Capacitance pf 2300
Insertion Loss db at range listed -59 50"
Maximum Drive Volts p-p 150
Rise Time Microseconds 1000
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 18
Bandwidth -6 db in kHz 1.8
 Power Input at rated Voltage Watts RMS 10
Typical Range* 20" - 150'
Housing Material PVC
Transmission Window Aluminum

Back to top


 Model Number 2010
Frequency kHz 20.5
Capacitance pf 2300
Insertion Loss db at range listed -61 50"
Maximum Drive Volts p-p 330
Rise Time Microseconds 1200
Temperature Range Degrees F 0 - 135
Beam Angle Total -6bd Pulse Echo Mode Degrees 10
Bandwidth -6 db in kHz 1.8
 Power Input at rated Voltage Watts RMS 10
Typical Range* 24" - 130'
Housing Material PVC
Transmission Window Aluminum

Back to top


*Range is dependent upon may factors. Best resultsare obtained with a flat target perpendicular to the sound field. Total lossin transmission is sum of spreading loss, sound absorption and target strength.Instrumentation must provide drive voltage and receiver gain necessary toovercome losses and provide adequate strength to trigger your logic.

Notes:
1. Designed primarily to use in pairs. Not recommended for pulse-echo use.
2. 2308F has a foam window primarily for use in solids.
3. See line drawings.

Back to top

Parsonics Corp.
935 Dieckman Street
Woodstock, IL 60098
PHONE 815-338-6509
FAX 815-337-0153
E-Mail info@parsonicscorp.com